Residential Building Inspection Report

 

501 Cincinnati Ave - Cincinnati, Ohio 45201

 

cincinnati

 

 

Inspection Date:

February 22, 2006

 

Prepared For:

Mr. & Mrs. Client

 

Prepared By:

House To Home Inspections LLC

513-255-0298

house2home@tds.net

Cincinnati office

 

Report Number:

00002129918

 

Inspector:

 John Murray

 

 

 

 

© 2006 House To Home Inspections-cincinnati -dayton ohio


 

Table Of Contents

 

 

 

:::::::::::::::::::::::This IS A REDUCED SIZED SAMPLE REPORT:::::::::::::::::::::::::

 

 

 

Report Overview                                                                                                                  3

Structure                                                                                                                                5

Roofing                                                                                                                                     11

Exterior                                                                                                                                   16

Electrical                                                                                                                              19

Heating                                                                                                                                      24

Cooling / Heat Pumps                                                                                                        27

Insulation / Ventilation                                                                                                 29

Plumbing                                                                                                                                  30

Interior                                                                                                                                    33

Appliances                                                                                                                              37

 


Report Overview

 

CONVENTIONS USED IN THIS REPORT

For your convenience, the following conventions have been used in this report.

Major Concern: a system or component which is considered significantly deficient or is unsafe. Significant deficiencies need to be corrected and, except for some safety items, are likely to involve significant expense.

Safety Issue:  denotes a condition that is unsafe and in need of prompt attention.

Repair: denotes a system or component which is missing or which needs corrective action to assure proper and reliable function.

Improve:  denotes improvements which are recommended but not required.

Monitor:  denotes a system or component needing further investigation and/or monitoring in order to determine if  repairs are necessary.

Please note that those observations listed under “Discretionary Improvements” are not essential repairs, but represent logical long term improvements.

 

IMPROVEMENT RECOMMENDATION HIGHLIGHTS / summary

The following is a synopsis of the potentially significant improvements that should be budgeted for over the short term.  Other significant improvements, outside the scope of this inspection, may also be necessary.  Please refer to the body of this report for further details on these and other recommendations.

 

THE SCOPE OF THE INSPECTION

All components designated for inspection in the NACHIâ Standards of Practice are inspected, except as may be noted in the “Limitations of Inspection” sections within this report.

It is the goal of the inspection to put a homebuyer in a better position to make a buying decision.  Not all improvements will be identified during this inspection.  Unexpected repairs should still be anticipated.  The inspection should not be considered a guarantee or warranty of any kind.

A Home inspection is a non-invasive visual examination of a residential dwelling, performed for a fee, which is designed to identify observed material defects within specific components of said dwelling.  Components may include any combination of mechanical, structural, electrical, plumbing, or other essential systems or portions of the home, as identified and agreed to by the Client and Inspector, prior to or during the inspection process.

I. A home inspection is intended to assist in evaluation of the overall condition of the dwelling. The inspection is based on observation of the visible and apparent condition of the structure and its components on the date of the inspection and not the determination of future conditions.

II. A home inspection will not reveal every problem that exists or ever could exist, but only those material defects observed on the day of the inspection.

1.2. A Material defect is a problem with a residential real property or any portion of it that would have a significant adverse impact on the value of the property or that involves an unreasonable risk to people on the property. The fact that a structural element, system or subsystem is near, at or beyond the end of the normal useful life of such a structural element, system or subsystem is not by itself a material defect.

1.3. An Inspection report shall describe and identify in written format the inspected systems, structures, and components of the dwelling and shall identify material defects observed. Inspection reports may contain recommendations regarding conditions reported or recommendations for correction, monitoring or further evaluation by professionals.

 

 

Please refer to the pre-inspection contract for a full explanation of the scope of the inspection.

 


Structure

description of Structure

 

Foundation:                                                       ·Concrete Block ·Basement Configuration 

Columns:                                                            ·Steel 

Floor Structure:                                               ·Wood Joist 

Ceiling Structure:                                           ·Joist 

Roof Structure:                                                ·Rafters ·Spaced Plank Sheathing 

Structure observations

 

 

 

recommendations / observations

Foundation

·         Monitor:  Common minor settlement cracks were observed in the foundation walls. This implies that some structural movement of the building has occurred. These cracks did not extend all the way through to the interior. Cracks of this type should be watched for any sign of additional movement. In the absence of any sign of ongoing movement, repair should not be necessary.

ohio

Back of House

home inspection

Side of House

 

 

Major Concern: Repair: Larger than typical foundation settlement cracking was observed. The amount of movement which has occurred is not likely to have caused other damage to the structure but this area should be repaired and continuously monitored. If additional movement occurs, more costly repairs might be necessary. The rate of movement cannot be predicted during a one-time inspection. House To Home Inspections recommends that a certified professional be called to further evaluate and repair.

 

 

cincy

Front of House. Paneling in basement restricted complete view.

home inspector

Crack under side basement window extends all the way into interior.

certified

Interior view of major crack above.

 

 

·         Improve: Surface deterioration (spalling, crumbling material) was observed on the back porch pad. This condition is common in many old homes and does not usually represent a serious structural concern unless there is substantial loss of material. In an effort to prevent long-term deterioration, it would be wise to consider parging (a concrete stucco-like coating) over deteriorated areas. Lot drainage improvements and elimination of water or roof runoff splashing against foundation walls as outlined in the Exterior section of this report are also recommended.

inspector

Floors

·         Monitor:  The floor structure shows common sagging and movement. This is usually the result of the age and framing design of the building. There was not evidence of need for immediate, costly repair.

·         Improve:  Main Steel support columns are not bolted or welded to main support beams throughout.

 

Wood Boring Insects

·         Monitor:  Although there was no visible evidence of prior or current termite damage or infestation, this home is in an area known for termite activity. Termites can do a substantial amount of damage to the wood structural components of a home. Any form of wood/soil contact should be avoided. Controlling dampness in the soil around the perimeter of a home, including below porches and in crawl spaces, is recommended. Preventative chemical treatment, performed by a licensed pest control specialist, is also advisable.

 

limitations of Structure inspection

As we have described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions:

·         Structural components concealed behind finished surfaces could not be inspected.

·         Only a representative sampling of visible structural components were inspected.

·         Furniture and/or storage restricted access to some structural components.

·         Engineering or architectural services such as calculation of structural capacities, adequacy, or integrity are not part of a home inspection.

The inspector is not required to:

Enter any crawlspaces that are not readily accessible or where entry could cause damage or pose a hazard to the inspector in his or her opinion.
B. Move stored items or debris.
C. Operate sump pumps with inaccessible floats.
D. Identify size, spacing, span, location or adequacy of foundation bolting, bracing, joists or support systems.
E. Provide any engineering or architectural service.
F. Report on the adequacy of any structural system or component.

Observed Limitations:

Access limited in side attic areas due to storage.

 

 

 

Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.

 


Roofing

description of Roofing

 

Roof Covering:                                                 ·Asphalt Shingle 

Roof Flashings:                                                ·Metal 

Chimneys:                                                          ·Masonry 

Roof Drainage System:                                ·Aluminum ·Downspouts discharge below grade 

Method of Inspection:                                   ·Walked on roof 

Roofing observations

 

General Comments

The roof coverings are old and are at or near end of useful life. 

recommendations / observations

Sloped Roofing

·         Monitor:  The roofing is near the end of its life. Watch for leaks and expect to replace the roof soon.

 

·         Repair:  An area of shingles is severely deteriorated and curled in the back. Damaged or missing roofing material should be repaired immediately.

cincinnati roof

 

·         It is recommended that the present layers of roofing materials be removed prior to re-roofing. This adds cost of demolition and debris removal to the re-roof cost.

master inspector

·         Replace the roof flashing materials when re-roofing to avoid leaks in these areas.

house to home inspections

Chimneys

·         Monitor:  The chimney is no longer in service. It could be removed down to a level below the roof line.

cincinnati flue

 

 

·         Repair:  Masonry chimney is cracked in the attic space. Some mortar joints need repaired.

home crack

Gutters & Downspouts

·         Monitor:  The downspouts that discharge below grade level should be monitored. If they are ever suspected to be clogged or disconnected below grade, they should be redirected to discharge at least five (5) feet from the building. Foundation leakage adjacent to a downspout is an indication of a problem below grade. A downspout discharge appears to have been unearthed in the backyard but, appears that it’s discharge is far enough away from the house.

Discretionary Improvements

Covering the gutters with a protective mesh may help to avoid congestion with leaves and debris.

 

limitations of Roofing inspection

As we have described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions:

·         Not all of the underside of the roof sheathing is inspected for evidence of leaks.

·         Evidence of prior leaks may be disguised by interior finishes.

·         Antennae, chimney/flue interiors which are not readily accessible are not inspected and could require repair.

·         Roof inspection may be limited by access, condition, weather, or other safety concerns.

The inspector is not required to:

A. Walk on any roof surface.
B. Predict the service life expectancy.
C. Inspect underground downspout diverter drainage pipes.
D. Remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces.
E. Inspect antennae, lightning arresters, or similar attachments.

Observed Limitations:

Storage in attic blocked access to side attic areas.

Chimney had material inside preventing inspection of interior

 

 

 

Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.

 


Exterior

description of Exterior

 

Wall Covering:                                                 ·Brick 

Eaves, Soffits, And Fascias:                       ·Wood ·Aluminum 

Exterior Doors:                                                 ·Metal 

Window/Door Frames and Trim:             ·Wood 

Entry Driveways:                                             ·Asphalt ·Concrete 

Porches, Decks, Steps, Railings:             ·Concrete 

Overhead Garage Door(s):                         ·Wood 

Surface Drainage:                                          ·Level Grade ·Graded Away From House 

Retaining Walls:                                             ·Block 

Exterior observations

Positive Attributes

The auto reverse mechanism on the overhead garage door responded properly to testing. This safety feature should be tested regularly as a door that doesn’t reverse can injure someone or fall from the ceiling. Refer to the owner’s manual or contact the manufacturer for more information. 

General Comments

The exterior of the home has not been well maintained. Repairs are needed. 

recommendations / observations

Exterior Walls

·         Repair:  Localized pointing of deteriorated mortar between the bricks of the exterior walls is advisable in a few locations to prevent further deterioration.

·         Repair:  The siding should be painted in front to preserve the building.

Exterior Eaves

·         Repair:  The fascia throughout should be painted.

Windows

·         Repair:  The window frames in various locations require painting and caulking. Exterior windowsills are cracked in some locations.

 

 

sill crack

Garage

·         Monitor:  The garage floor slab and walls have typical cracks usually the result of shrinkage and/or settling of the slab. Floor cracks more than 1/8” high could present a trip hazard.

·         Improve:  Shed is dilapidated in back.

·         Repair: Front storm door closer missing.

Driveway

Monitor:  Common minor cracks throughout.

Walkway

·         Repair, Safety Issue:  The walkway along the left hand side of the home presents a trip hazard. This condition should be altered for improved safety.

 

limitations of Exterior inspection

As we have described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions:

·         A representative sample of exterior components was inspected rather than every occurrence of components

that were tested.

The inspector is not required to:

A. Inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting.
B. Inspect items, including window and door flashings, which are not visible or readily accessible from the ground.
C. Inspect geological, geotechnical, or hydrological conditions.
D. Inspect recreational facilities.
E. Inspect seawalls, break-walls and docks.
F. Inspect erosion control and earth stabilization measures.
G. Inspect for safety type glass.
H. Inspect underground utilities.
I. Inspect underground items.
J. Inspect wells or springs.
K. Inspect solar systems.
L. Inspect swimming pools or spas.
M. Inspect septic systems or cesspools.
N. Inspect playground equipment.
O. Inspect sprinkler systems.
P. Inspect drain fields or drywells.
Q. Determine the integrity of the thermal window seals or damaged glass.

Observed Limitations:

·         Landscape components restricted a view of some exterior areas of the house.

·         Storage in the garage restricted the inspection.

·         Access below decks and/or porches was not possible.

 

Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.

 


Electrical

description of Electrical

 

Size of Electrical Service:                          ·Unable To Determine 

Service Drop:                                                   ·Overhead 

Service Entrance Conductors:                  ·Aluminum 

Service Equipment &

Main Disconnects:                                          ·Main Service Rating ??? Amps  ·Breakers